Process historian, APC and plant-data notes

Engineer-written notes on RIMX (process historian and real-time database), APC payback, OPC UA, MQTT, operator training and industrial AI. Written for people who run units — and structured so search engines can find them.

12 Nov 2026 · Energy

Specific energy without a production-mode mask is not a KPI

∑energy / ∑product only in production mode. A turnaround week is not a saving — and not an APC baseline.

12 Nov 2026 · Industrial data

InfluxDB is not a process historian

A TSDB stores numbers. Plant history also needs OPC quality, operating mode and a tag owner on the unit.

12 Nov 2026 · Engineering insight

Fix the PIDs before you buy APC

If loops hunt or sit on a limit, the multivariable controller will be put in manual. Audit the 8–15 MV loops first.

12 Nov 2026 · Industrial data

When a PI-class historian is the wrong first buy

SME plants with Excel extracts need a working real-time database, not an enterprise historian they cannot staff.

12 Nov 2026 · Technical note

How many tags belong in a first historian pilot?

One unit, about 50–300 tags you already trend, and one report operations asked for — not the whole DCS.

12 Nov 2026 · Technical note

Why the daily plant report should not live in Excel

A workbook-only KPI is a copy-paste ritual. Calculate it from historian tags with a production-mode mask.

10 Nov 2026 · Industrial data & AI

Why industrial AI starts in the process historian, not the data lake

Time-aligned tags, OPC status and operating mode are what models inherit. RIMX keeps that context so Python, KPIs and later AI stay honest.

10 Nov 2026 · Analytics

Soft sensors in RIMX: inferring quality when the analyzer is late

2024–2025 process-control papers treat multi-rate lab samples as the real problem. Build inferentials on historian tags, then show them next to the lab.

10 Nov 2026 · Industrial AI

Anomaly detection on process data that operators will actually use

Mode masks, a short tag list, and alerts that name the excursion — before a deep multivariate model on the whole DCS.

10 Nov 2026 · Integration

OPC UA, MQTT and REST on one RIMX platform — without replacing the historian

A Unified Namespace is live state. The historian is history. Use OPC UA for the DCS, MQTT for packages, REST for IT.

10 Nov 2026 · Industrial AI

What to ask before putting an LLM next to the unit

NAMUR NE178 Verification of Request and Fraunhofer LLM4OPC: read-only retrieval first, human approval for any write.

10 Nov 2026 · Operator training

Replay plant history into operator training: RIMX and Apogee OTS

Turn trips, start-ups and golden batches in the historian into OTS scenarios crews will recognise.

10 Nov 2026 · Technical note

Calculating unit KPIs with Python in RIMX

Specific energy, yield, quality sigma and utilisation from historian tags — integrate, then ratio, with a production-mode mask.

10 Nov 2026 · Engineering insight

When does APC pay back? A practical checklist

Constraint, baseline, healthy PIDs and a named owner. Literature payback is months to two years; most applications fade without maintenance.

10 Nov 2026 · Integration guide

Connecting a DCS to RIMX over OPC UA

Certificates, SignAndEncrypt, read-only subscriptions and Historical Access — the DCS stays the controller.

Have a process problem worth solving?

Talk to an engineer, not a salesperson. Tell us about your unit and we will suggest where to start.

Request a technical consultation Request a RIMX demo